PFM920I-6UN-C

305 m UTP CAT6 Cable – Oxygen free copper (99.97% purity)

> 305 m (1000 ft)/carton UTP CAT6, power over Ethernet, compatible with one cable

> High-purity oxygen-free copper conductor

> Customized PVC outer sheath; CE CPR Eca flame retardant class certified

> 10-year warranty

PFM920I-6UN-C

Category
Description
Conductor
MaterialOxygen free copper (99.97% purity)
Diameter0.53 mm ± 0.01 mm
Insulation
MaterialHDPE
Min. Average Thickness0.21 mm
Diameter0.95 mm ± 0.1 mm
Color (4 Pairs)Blue, white/blue; orange, white/orange; green, white/green; brown, white/brown
Separator
MaterialPE
SpecificationTranslucent 4.5 × 0.4 mm
Rip Cord
MaterialPolyester
Specification500D
Sheath
MaterialPVC
Min. Average Thickness0.5 mm
Diameter6.0 mm ± 0.3 mm
ColorWhite
Electrical
Max. DC Resistance of a Single Conductor8.7Ω/100 m
Min. Insulation Resistance5000MΩ·km
Max. DC Resistance Unbalance2% (pair intra), 4% (pairs inter)
Dielectric StrengthNo breakdown with 1KV DC for 1 min
Transmission
Characteristic Impedance100 ± 15Ω
Near End Cross Talk≥39.30 dB/100 m@250 MHz
Max. Attenuation34.8 dB/100 m@250 MHz
Return Loss≥17.3 dB/100 m@250 MHz
Mechanical
Tensile StrengthSheath≥13.5 MPa, insulation≥16 MPa
Elongation at BreakSheath≥150%, insulation≥300%
Installation Bending Radius>8 times of outer cable diameter
Conductor Elongation at Break≥10%
Environmental
Shrinkage of Insulation≤5%
Color Migration Resistance of InsulationNo migration
Sheath Tensile Strength and Elongation at Break after Aging≥12.5 MPa, ≥100%
Low Temperature Bending TestNo cracking after the test
Heat Shock TestNo cracking after the test
Operating Temperature–20°C to +60°C (–4°F to 140°F)
Installation Temperature0°C to +50°C (32°F to 122°F)
Storage Temperature and Humidity–10°C to +40°C (14°F to 104°F), <60% (RH)
Security
Vertical Fire Propagation TestComply with IEC 60332-1-2
Packaging
Cable Length305.0 m (1000.66 ft) ± 1.5 m (4.92 ft)
Inner Carton Dimensions416.0 mm × 412.0 mm × 220.0 mm (16.38″ × 16.22″ × 8.66″) (L × W × H)
Packaging Method305.0 m (1000.66 ft) a carton, 36 pcs/pallet
Net Weight≥10.5 kg (23.15 lb)
Gross Weight≥11.5 kg (25.35 lb)
Compliance
Executive StandardsQ/DXJ 067-2019, EN50575-2014
Certification
CertificationCPR Eca
Transmission Characteristics

(100 m at 20°C) (328.08 ft at 68°F)

Frequency (MHz)Phase delay ≤ nsIL ≤ dBTCL≥ dB﹡EL TCTL≥ dB﹡NEXT ≥ dBPS NEXT ≥ dB
1n/sn/s50.035.0n/sn/s
4552.04.044.023.066.363.3
8547.05.641.016.961.858.8
10545.06.440.015.060.357.3
16543.08.138.010.957.254.2
20542.09.037.09.055.852.8
25541.010.136.07.054.351.3
30﹡540.611.035.25.553.150.1
31.25540.011.335.1n/s52.949.9
62.5539.016.332.0n/s48.445.4
100538.021.030.0n/s45.342.3
200537.030.727.0n/s40.837.8
250536.034.826.0n/s39.336.3
Frequency (MHz)EL FEXT ≥ dBPS EL FEXT ≥ dBRL ≥ dBDelay skew ≤ nsZc(Ω)
1n/sn/sn/sn/sn/s
456.053.023.045.0100±15
849.946.924.5
1048.045.025.0
1643.940.925.0
2042.039.025.0
2540.037.024.3
30﹡38.535.523.8
31.2538.135.123.6
62.532.129.121.5
10028.025.020.1
20022.019.018.0
25020.017.017.3
Note:

Executive standard for the above parameters: Q/DXJ 067-2019

“n/s”=Not Specified

“﹡”=Unless otherwise customer stated the test results default to not shown in test report but comply with standard